Opel Vectra B

Since 1995 of release

Repair and car operation



Opel of Vektra
- 1.1. Controls and control devices
   1.2. A combination of devices
   1.3. Control bulbs
   1.4. The counter of the passed way and hours
   1.5. The Triple-Info-display
   1.6. The Multi-Info-display
   1.7. The Multi-Info-display - Check-control
   1.8. The Multi-Info-display - the Onboard computer
   1.9. Heating and ventilation system
   1.10. The conditioner
   1.11. Heating
   1.12. The electronic climate control
   1.13. System TC
   1.14. Cruise-control
   1.15. The catalyst
   1.16. A signalling device of electronic system of the engine
   1.17. System of release of the fulfilled gases
   1.18. An automatic transmission
   1.19. Instructions on driving
   1.20. Economy of fuel
   1.21. A fuel grade
+ 2. Maintenance service
+ 3. Engines
+ 4. Heating, ventilation
+ 5. Fuel system
+ 6. Systems of start, ignition
+ 7. Transmission
+ 8. Brake system
+ 9. A running gear
+ 10. A body
+ 11. An electric equipment
+ 12. The basic malfunctions



1.10. The conditioner
THE GENERAL DATA

Systems of heating, ventilation and the refrigerating unit form the uniform functional block calculated for achievement of the maximum comfort at any time of year, under any weather conditions and external temperatures.

The refrigerating unit of the conditioner cools air and deletes from it a moisture.

At the included refrigerating unit the fuel expense raises. If there is no requirement for cooling the conditioner should be switched off.

The filter of clearing of air clears air arriving outside of a dust and soot, and also from pollen and dispute.

The heater heats up air in any operating conditions at will, according to position of a regulator of temperature. Air access is carried out by the fan and can be regulated according to individual requirements.

The temperature regulator, regulator of distribution of air and the fan switch blowing have the same functions, as at group of switches of system of heating and ventilation.

Over group of switches of system of heating and ventilation there are switches: air circulation and air-conditioning systems.

By means of the central air switch the refrigerating compressor of the conditioner (an inclusion signalling device) joins. The fan blowing rotates with small frequency which can be raised at will.

By means of the switch of system of air circulation the system in an air circulation mode (an inclusion signalling device) is switched.
At receipt of a smoke or unpleasant smells outside: temporarily to include air circulation system.

The refrigerating compressor is automatically switched off at external temperature approximately more low +4 ° With.

Air-conditioning mode

The maximum cooling

To open for some time of a window that heated up air could disappear faster.

 – To include the conditioner;
 – To include a circulation mode;
 – To establish a temperature regulator in extreme left position (coldly);
 – The fan switch blowing to establish in position 4;
 – A regulator of distribution of air to establish in position;
 – To open all nozzles blowing.

Normal cooling

 – To include the conditioner;
 – To switch off a circulation mode;
 – To establish a temperature regulator in extreme left position (coldly);
 – To include the fan blowing at will;
 – A regulator of distribution of air to establish in position;
 – To open all nozzles blowing.

Ventilation without cooling

 – To switch off the conditioner;
 – To switch off a circulation mode;
 – To establish a temperature regulator in the left position;
 – To include the fan blowing at will;
 – A regulator of distribution of air to establish in position;
 – To open nozzles blowing.

Additional ventilation of space for feet:

 – A regulator of distribution of air to establish in position.